Please use your Web Browser's 'Back' Button to return to our Products Page

S.B.I SPRAYHEAD TYPE V

 

Specifications
Type: V
Diameter: 90 mm
Drilling: 3/32" holes
Coverage: Directional Bais
Function: For cleaning vertical cylindrical vessels via a dummy manway or an existing inlet pipe in the side of the vessel. Orientation of the 'R' Clip Fixing is important.

 

S.B.I Sprayhead Optimum Discharge Pressure at Sprayhead Flowrate Effective Cleaning Radius
Type lbs/in sqr bar gal/min ltr/min ft. m
V 14-50 .95-3.40 50-100 91-455 12 3.65

 

 

Typical installation of SBI Sprayhead Type V Dimensions of S.B.I Sprayhead Type V
A 12 ft (3.65 m) Max. A 68 mm
B 12 ft (3.65 m) Max. Dia. B 40 mm
C 90 mm
D 2.8 mm 'R' Clip Fixing
E 38.4 mm I.D. Tube (1.5 in. Inlet)
F Holes for directional throw